BOC+
Design Calculations for Slurry Injections in Saturated Zone
|
|
Technical Support 773-792-2304
|
|
|
|
Consultant:
|
|
|
|
Project Name:
|
|
Ver.1.1
|
|
Project Location:
|
|
|
|
Design Perimeters of Groundwater Plume
|
|
Width
(perpendicular to Groundwater flow direction)
|
|
feet
|
Plume Area
|
|
ft2
|
|
Length
(parallel to groundwater flow direction)
|
|
feet
|
Total Cubic Feet
|
|
ft3
|
|
Depth to Contaminated Zone
|
|
feet
|
Treatment Pore Volume
|
|
ft3
|
|
Thickness of Contaminated Saturated Zone
|
|
feet
|
Weight of Pore Water
|
|
lbs.
|
|
Total Porosity (see footnote)
|
|
-
|
Weight of Soil
|
|
lbs.
|
|
Effective Porosity
|
|
-
|
Weight of Soil
|
|
kg
|
|
Fraction
of Organic Carbon (foc)
|
|
-
|
|
|
|
|
Hydraulic Conductivity
|
|
feet/day
|
Soil Bulk
Density
|
|
lbs./cubic foot
|
|
Hydraulic Gradient
|
|
feet/foot
|
Seepage Velocity
|
|
feet/day
|
|
Dissolved Water Phase Oxygen Demand
|
Max. Conc.
|
Contaminant
Mass
|
Stoic. Wt. of O2 Req'd.
|
O2 Required
|
BOC+
Reqired
|
|
|
|
mg/L
|
lbs.
|
|
lbs.
|
lbs.
|
|
Benzene
|
|
|
3.1
|
|
|
|
Toluene
|
|
|
3.8
|
|
|
|
Ethyl Benzene
|
|
|
3.2
|
|
|
|
Xylenes
|
|
|
3.2
|
|
|
|
MTBE
|
|
|
2.7
|
|
|
|
Reduced Metals Fe(+2), Mn(+2), etc.
|
|
|
|
|
|
|
Add Chemical of Concern and Stoichiometric Demand,
Call BioRenova
|
|
|
|
|
|
|
Add Chemical of Concern and Stoichiometric
Demand, Call BioRenova
|
|
|
|
|
|
|
Total Petroleum Hydrocarbons (TPH)
|
|
|
3.1
|
|
|
|
Chemical oxygen Demand (COD), For Soil Test Call BioRenova
|
|
|
1.0
|
|
|
|
Estimate of Soil Contaminant Mass = foc x Koc x Conc. x wt.
Soil, Modify koc so to provide practical estimate
|
|
Sorbed Phase
Oxygen Demand
|
Koc
|
Concentration
|
Contaminant
Mass
|
Stoic.
Wt. of O2
Req'd.
|
O2 Required
|
BOC+ Req'd
|
|
|
|
|
|
mg/kg
|
lbs.
|
|
lbs.
|
lbs.
|
|
Benzene
|
|
|
|
|
|
|
|
Toluene
|
|
|
|
|
|
|
|
Ethyl Benzene
|
|
|
|
|
|
|
|
Xylenes
|
|
|
|
|
|
|
|
MTBE
|
|
|
|
|
|
|
|
Add Chemical of Concern and Stoichiometric Demand,
Call BioRenova
|
|
|
|
|
|
|
|
Add Chemical of Concern and Stoichiometric Demand,
Call BioRenova
|
|
|
|
|
|
|
|
Total Petroleum Hydrocarbons (TPH)
|
|
|
|
|
|
|
|
Chemical oxygen Demand (COD), Soil Test Value
|
Soil Test
|
|
|
|
|
|
|
Purchase Cost
|
Enter Purchase Costs for Comparison
|
|
|
|
Calculated
estimate of oxygen required below, represent 3 different approaches, use the
highest lbs. of material req'd where appropriate
|
Dissolved Phase Demand
|
Sorbed Phase Demand
|
Safety
Factor
|
BOC+ Reqired at 18% O2/lb
|
Approx.Cost of
BOC+
|
|
|
lbs. O2
|
lbs. O2
|
|
lbs.
|
$
|
|
|
1 - BTEX, MTBE, Reduced Metals and/or VOCs
|
|
|
|
|
|
|
|
2 - Total Petroleum Hydrocarbons - TPH
|
|
|
|
|
|
|
|
3 - Chemical Oxygen Demand - COD
|
|
|
|
|
|
|
|
Notes: All Calculations are rounded
up, For Soil Porosity use: Sand
(loose=0.46, mixed=0.4; dense: uniform=0.34, mixed=0.3) Clay (soft=0.55,
stiff=0.37).
|
|
For Soil COD Test Method, Call BioRenova
|
|
|
Yellow boxes indicate
variables to be input by user.
|
|
|
Chemicals of concern that degrade aerobically and their
Stoichiometric demand can be added so to determine total oxygen demand
required and approx. cost of material.
|
|